The Howard-Dolman Test
Abstract
The Howard-Dolman Test is a quantitative assessment tool used in orthoptics to measure stereoscopic depth perception and stereoacuity. It evaluates an individual's ability to perceive relative distances by manipulating the position of two vertical rods.
Depth Perception Assessment, stereopsis
Test Components
- Two vertical rods (black or white)
- One fixed rod (stationary reference)
- One movable rod
- Viewing apparatus with rectangular aperture
- Pulley system or manual control mechanism
- Standard viewing distance: 6 meters
Test Specifications
- Illumination: Standard room lighting
- Rod dimensions: Typically 15cm height, 1.5cm width
- Viewing window: Approximately 7.5cm x 3cm
- Background: Usually black or neutral gray
Testing Procedure
Setup
1. Position patient at exactly 6 meters from apparatus
2. Ensure proper illumination
3. Verify patient wearing appropriate correction
4. Confirm binocular vision status
Administration
1. Patient views both rods through aperture
2. Movable rod positioned randomly in front or behind fixed rod
3. Patient adjusts movable rod position
4. Goal: Align both rods at same apparent distance
5. Multiple trials performed (typically 8-10)
Measurement and Recording
Data Collection
- Record distance deviation from fixed rod in millimeters
- Note direction of error (anterior or posterior)
- Calculate average deviation
- Document standard deviation
Calculations
1. Stereoscopic threshold = (Mean deviation × 2)
2. Stereoacuity in seconds of arc = tan⁻¹(threshold/viewing distance)
Result Interpretation
Normal Values
- Adults: 2-7 seconds of arc
- Children: May be slightly higher
- Threshold increases with age
Clinical Significance
Normal Results
- Good stereopsis
- Functional binocular vision
- Adequate depth perception
Abnormal Results
- Reduced stereoacuity
- Potential binocular vision dysfunction
- Possible ocular misalignment
Clinical Applications
Primary Uses
1. Quantifying stereoacuity
2. Monitoring binocular vision disorders
3. Occupational screening
4. Post-treatment evaluation
Advantages
- Quantitative measurement
- Objective assessment
- Good reliability
- Real-space testing
Limitations
- Requires dedicated apparatus
- Fixed testing distance
- Time-consuming
- Space requirements
Special Considerations
Testing Conditions
- Proper room illumination
- Accurate viewing distance
- Patient alertness
- Clear instructions
Common Sources of Error
1. Incorrect viewing distance
2. Poor illumination
3. Patient fatigue
4. Monocular cues
Professional Applications
Occupational Assessment
- Aviation industry
- Military personnel
- Industrial workers
- Professional drivers
Clinical Monitoring
- Strabismus treatment
- Vision therapy progress
- Surgical outcomes
- Amblyopia management
Conclusion
The Howard-Dolman Test remains a valuable tool in orthoptic practice for quantitative assessment of stereopsis. While more modern alternatives exist, its real-space testing environment and quantitative nature make it particularly useful for specific clinical and occupational applications.
Note : This document serves educational purposes exclusively and does not constitute medical advice or treatment guidelines