OCTOPUS 900 PERIMETER
Abstract
Advanced automated perimetry systems (Haag-Streit) for comprehensive visual field testing and glaucoma management. Features LED-based stimuli with Goldmann-equivalent parameters and delivers accurate results in 2.5-4 minutes per eye.
Official Website
Technical Specifications
Projection System: 90-degree cupola with full 180-degree peripheral testing capability
Stimulus Generation: LED-based projection system
Background Illumination: Standard perimetric levels
Stimulus Sizes: Goldmann stimulus sizes I to V
Stimulus Intensities: Goldmann-equivalent intensities 1a to 4e
Stimulus Colors: White and red stimuli available
Angular Velocity: Variable stimulus speed control
Bowl Design: Original Goldmann bowl with 30 cm radius in all directions
Clinical Programs
Standard Programs: 24-2, 30-2, and 10-2 test patterns
Testing Modes: Full field static and kinetic perimetry
Glaucoma Detection: G program for targeted testing of compromised vision areas
Test Duration: Standard white-on-white threshold testing in 2-4 minutes for central visual field
Early Detection: Results available in 2.5 minutes with 100% fixation control
OCTOPUS 600 PERIMETER
Technical Specifications
Stimulus Generation: TFT Monitor
Peripheral Range: 30° (infinite distance)
Background Illumination:
SAP: 10 cd/m²
Pulsar: 32 cd/m²
Stimulus Size:
SAP: 0.43° (Size III)
Pulsar: 5°
Stimulus Duration:
SAP: 100 ms
Pulsar: 500 ms
Stimulus Intensity: SAP: ~35 dB dynamic range; Pulsar: ~35 src
Physical Dimensions: 467 × 508 × 500 mm (W × L × H)
Weight: 12.7 kg (28.0 lbs)
Fixation Control Systems
Blink Control, Pupil Position Control, Dart Control, Contact Control
Testing Technologies
Standard Automated Perimetry (SAP): Standard white-on-white perimetry
Pulsar Perimetry: Early detection technology
SHARED FEATURES (Both Models)
Software and Analysis
EyeSuite Integration: Ability to integrate into existing networks using EyeSuite software
Progression Analysis: Cluster and polar graphs for immediate change visualization
Printout Options: Standard 7-in-1 printout, customizable 4-in-1 printout, serial printout
Connectivity
Networking: DICOM, EMR, Ethernet capabilities
Data Import: Compatible with Octopus 101, 123, 300, and 900; HFA data
User Interface
Display: Touch screen interface (600 model)
Operation: Compact-sized with simplified perimetry for streamlined operation
Clinical Applications
Glaucoma Management: Early glaucoma detection screening with 100% fixation control
Test Speed: Accurate results in 2.5 minutes
Both systems are designed for comprehensive visual field analysis with the Octopus 900 offering more advanced kinetic perimetry capabilities and the Octopus 600 focusing on efficient static perimetry with Pulsar technology for early glaucoma detection.